Ruskin dampers. g. Ruskin dampers

 
gRuskin dampers  (2) ‘E’ Clips 3

@ 4" w. Dynamic fire dampers shall be Ruskin model DFD60-3. Fire/smoke dampers must be installed so the leading edge of the closed blades are within the barrier it is intended to protect (unless specifically designed for out of wall or floor applications). If the actuator must be mounted on top or bottom, select the FSD60V. These UL Classified dampers protect against heat, as well as flame, in ceilings with fire resistance ratings of 3 hours or less. Combination louvers can incorporate both drainable and non-drainable blades which are selected based on the structure. Get a Quote. 75" w. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowon dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. AXLE All axles to extend 6" (152) beyond damper frame. The bubble tight isolation damper shall be manufactured in an ISO9001 certified factory. Mounting angles must overlap the partition a minimum of 1" (25). A. L586) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood True Round Grille or through ceiling membrane penetrationRuskin February 222 Page 1 FDR25 Galvanized Steel True Round Fire Damper 1 1/2 Hour UL555 Rating for use in Dynamic & Static Systems Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. Life Safety » Combination Fire/Smoke Dampers 1. DAMPER SIZESRuskin CD60 Commercial Control Dampers Type for a low price! Get free shipping on orders over $999!. D-DIA. Share this page: Guillotine "fire damper" fabricated from a fire resistant panel used in the construction of 3 hour UL tested and labeled sliding fire doors. Pottorff is a leading manufacturer of AMCA- and UL-certified HVAC louvers and dampers for commercial applications. The damper is rated for Ruskin CD50DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Actuators & Damper Accessories Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin continues to provide the industry with the most UL approved field installation solutions for fire and fire/smoke dampers. Combination Fire/Smoke dampers are low leak damper and actuator assemblies that have passed the UL555 and UL555S test requirements. Ruskin® was founded in the Ruskin Heights area of Kansas City in 1958. This damper has insulated extruded aluminum blades with a thermal break and twin blade edge seals that ensure low leakage and reliable performance. For proper operation, damper must be installed square and free from racking. Butterfly blade. appliCaTion CFD7 is the first Ceiling Radiation Damper to be UL listed for 2” x10” or 2” x 12” wood joist assemblies (Ref. Industrial Multi-Blade Control Damper. • Airfoil blade design for low pressure drop and reduced noise generation. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. Home; PRODUCTS Air Control and Backdraft Dampers Ceiling Radiation Dampers. It features: 750 degree F standard temperature rating! A variety of applications in air and material volume control systems. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. Ruskin Literature. Specifying and installing low-leakage dampers (Class 1 preferred, Class 2 at a minimum by code) helps ensure that the building HVAC system is operating at its most energy-efficient level. &nbsp;Examples include: &nbsp;industrial. Carbon steel construction. Corrosion. 1. V Groove & Single Blades. FILES (0) Share this page: Catalog. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. 8955 DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. It is made of durable PVC materials and has a simple design that allows easy installation and operation. , Ruskin does not recommend using these designs in systems with velocities greater than 2000 fpm. The Ruskin Company’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. The blades are the same thickness throughout the shape, optimizing the R-Value rating. SP100: Dampers shall be equipped with factory installed damper position indication switch package. back pressure depending on damper size. The. Every damper is built with performance in mind and tested per AMCA standards. Ruskin UL listed solutions are available. Unlike conventional mounting angles that can-not be fastened together in the corners and ship separately from the dampers, the FAST and PFMA are: • One piece angles (fastened together in the corners)- Single section dampers ordered with either 12” (305), 14” (356) or 16” (406) long sleeve; the IBD20, 40, 60, 230, 430 and 630 models may be substituted. The barometric bypass dampers relieve excess air in duct systems through the use of a counter-balanced controlled arm weight. The damper shall be rated for dynamic closure at 2000 fpm (10. F. Grandview, MO 64030 View our location on Google Maps Phone: 816. Ruskin® offers a comprehensive guide to its commercial dampers, including product features, specifications, installation instructions, and 3D Revit® files. The EFL is STANDARD on all fire/smoke dampers ordered with electric actuators. Keywords: Ruskin, Commercial, backdraft, damper S3G, Data, Submittal, galvanized, steel Created Date: 1/5/2017 12:58:19 PMRUSKIN finishes enhance product appearance to blend with other colors selected. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). A complete line of damper products for fire and smoke control in life safety systems and for airflow control in commercial HVAC and industrial systems. TDP05K Placement Tool. The FDR25SS is rated for maximum velocity of 2,000 fpm and 4” w. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). rectangular, airfoil, class IA leakage, heavy duty, 6000 FPM, 13" w. The CD35 commercial control damper offers sturdy, steel construction with interlocking frame design. TION 1. Ruskin CFD model ceiling fire dampers provide the appropriate protection needed for openings in fire rated ceilings. 5. The CD80AF2 Industrial Control damper has an 8" frame. Standard damper assemblies are furnished ¼” smaller. PRESSURE DROP INFORMATION Performance curves based on AMCA Standard 500 using test setup apparatus figure 5. Haldeman is a stocking Manufacturer Representative and Distributor of HVAC products since 1933. Ruskin was founded in the Ruskin Heights area of Kansas City in 1958. S3G Back Draft Damper Product Data/Submittal Author: Ruskin Authority in Air Control - Subject: Ruskin s S3G Commercial backdraft damper has a 3" (76) frame and is constructed of galvanized steel. lbs. It can be equipped with the industry's shortest sleeve and is ideally suited for shaft wall applications. OPTIONS True Round Fire Damper See model FDR25. | Ruskin. Dampers can be constructed of galvanized, stainless, or aluminum and are available with a diverse compliment of. 5. It features: Vertical blades. Built from strong materials and designed on state-of-the-art equipment, they are perfect for demanding conditions. be-csd-thailand@jci. Specifier Select Option Dampers shall be equipped with factory installed damper. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. 350° Vertical or Horizontal SIze StAtIC PReSSURe teMPeRAtURe INStALLAtIoN ACtUAtoR ReqUIReMeNtS * UL555S requires that all. Specifier Select Option Dampers shall be equipped with factory installed damper position indication switch package. GENERAL INSTALLATION NOTES 1. Dynamic fire dampers shall be Ruskin multiple model DFD60. The CDR82 Round Control Damper features: Accurate airflow control within round ductwork systems in medium pressure industrial HVAC systems Desired performance easily attained in pressure differentials of 6"w. Ruskin fire/smoke dampers can be rotated or turned over to accommodate the application. Has airfoil blades, which have greater strength, provide superior sealing, and produce less noise. Masonry/Wall or Floor: #10 self-tapping concrete screws. The TS150 is an optional device which can be ordered with electric actuators or pneumatic actuators and EP (electro/pneumatic) switches. Readily connects to round spiral or flexible ductwork. g. Fiberglass Dampers. Quick Select. Each has added features that enable them to meet all high temperature, high pressure airflow. Greaves Rd. Model CFM Static Pressure Throw In Feet Neck Velocity Jet Velocity Noise Level. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. Closes and locks the damper via a standard replaceable fuse link when the specified temperature is is detected. Aluminum Airfoil Blades. Louver Paint Finishes - Color Guide. It features: Accurate airflow and isolation at extreme elevated temperatures. The CD40 Series has 6" wide V-grooveThe PFL is a UL Classified heat responsive device used in conjunction with Ruskin fire/smoke dampers. back pressure depending on damper size. The damper and sleeve assembly can be installed completely from one side of the wall and does not require mounting angles on the backside. The ARD25 is. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. 2 m/s) and 4” w. Location of Damper in Ductwork Smoke Dampers must be placed in the ductwork so the closed blades are within 24” (610) of the smoke barrier and before any duct inlets or outlets (access doors not included). Sizes to fit round openings up to 20" diameter and rectangular openings up to 24" x 24" are available. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowSun Control Sunshades. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. Determine area factor for damper by entering the Area Factor Table through duct width and height. Noise Control. would require CD50 damper with maximum section width of 36" (914). dampers. Ruskin model CD50IF offers HVAC design engineers an ultra-low leak high performance damper which provides: AMCA Class 1A leakage for energy savings Integral 1 ½” flange (front or rear) Mechanically fastened blade edge seals for longevity Shake proof linkage for low maintenance. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below on dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. Built from. For damper styles WR, WC, WO and BC only the duct connection portion extends through the wall and the damper. Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . 7476 Fax: 816. The BD6 backdraft damper is ideally suited to heavy duty applications and is AMCA certified for Leakage and Performance. Multiple models are intended for diverse heavy duty applications, and can be manually or automatically controlled using factory installed and commissioned actuators. DIBD2GA fire dampers are idealAMCA Publication 500. Each has added features that enable them to meet all high temperature, high pressure. Industrial FAQs. ©Ruskin 2002 FRAME QTY. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD50-CE. Dampers may tolerate higher pressures and velocities than those listed here. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). Ruskin model CD60 offers HVAC design engineers an ultra-low leak high performance damper which provides: • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Insulating Control Dampers. Issue ‘E’ Fuse Link 4. Ruskin® Labor Saversfor fire and fire/smoke dampers include factory sleeves, PFMA mounting angles, and tagging by floor or by area. of damper with minimum of 20 in. 3. 8) steel. Refer to the UL approved installation instructions for specific requirements. CD60SS SUGGESTED SPECIFICATION Furnish and install, at locations shown on plans, or in accordance with schedules AMCA certified, low leakage airfoil control dampers meeting the following minimum construction standards. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. Fire/smoke dampers must be installed so the leading edge of the closed blades are within the barrier it is intended to protect (unless specifically designed for out of wall or floor applications). These UL Classified dampers protect against heat, as well as flame, in ceilings with fire resistance ratings of 3 hours or less. The product is not cancelable or returnable unless found defective. It features: Airfoil blades, which have greater strength, less static pressure, superior sealing ability, superior fire protection ability and produce less noise. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. Johnson Controls offers a broad range of HVAC dampers and louvers engineered to fit your unique application and size requirements. 5" w. Leakage ratings are based on AmCA Standard 500 using Test Setup Apparatus Figure 5. Details shown do NOT APPLY if your control damper has any of the following fea-tures: 1. Curtain Type Static Fire Dampers 1 1/2 Hour UL555 Rated For Use In Static System Ruskin Model IBD20, 40, and 60 are 1 1/2 hour UL classified static (fans off) curtain style fire dampers for use in HVAC systems that shut down during a fire event. Face and by-pass arrangement. g. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. The CFD2 is a UL555C Classified Ceiling Fire Damper. Consult Ruskin or your Ruskin repre-sentative when a damper is to be applied in conditions exceeding recommended maximums. Ruskin model CD50IF offers HVAC design engineers an ultra-low leak high performance damper which provides: AMCA Class 1A leakage for energy savings Integral 1 ½” flange (front or rear) Mechanically fastened blade edge seals for longevity Shake proof linkage for low maintenance This catalog offers Damper customers an easy to use buying guide for miscellaneous Ruskin Damper parts. FSD36 126"x 96"or 72"x 122" 4"w. When installed as shown, they provide appropriate protection for air inlet or outlet penetrations in the ceiling membrane of floor/ceiling and roof/ceiling assemblieslabel and is classified as a static damper for use in HVAC systems that shut down during a fire. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. UL qualifies the damper and its actuator for performance after 30 minute exposure to elevated temperatures. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. INSTALLATION For proper operation, damper must be installed square and free from racking. the following control damper models: CD50 CD504 CD40 CD403 CD51 T-Flange frame is available at additional cost for the following Ruskin commercial control damper models: CD60 CD36 CD356 IL35 CD35 CD355 MINIMUM SIZE Models CD50, CD504, CD60, CD356 and CD355, 6" x 4" (152 x 102). 500. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. Welcome to Ruskin Rooftop Systems 972. Ruskin Literature. Face and by-pass. 5, CFD4 and CFD(R)5 are UL labeled ceiling radiation dampers. per sq. Higher velocities are not recommended for outside air openings, due to water penetration concerns. 3 m/s) and 8” w. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. a. CFD7T - 2"x4" Truss Assemblies (Ref. ft. The DTS gives maintenance personnel the ability to “cycle test” the fire/smoke damper by pushing and holding the button until the damper has cycled. Fire/smoke dampers ordered with pneumatic actuators may be ordered with the EFL and and. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. Certain actuators in Table 1 are UL Recognized Components under. ©Ruskin February2016 Model FSD60GA and FSD36GA series meet the requirements for combination fire and. NOTE:CD355 and CD356 STANDARD CONTROL DAMPERS GALVANIZED STEEL FEATURES Sturdy, steel construction features interlocking frame design. This folder features all of the latest literature that Ruskin has produced, available in. 25" w. Greaves Rd. Maximum rating of 2,000 fpm and 4" w. Figure 5. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. UL approval for dual directional air flow. Swartwout series model 426 Round Fiberglass Backdraft Damper Molded fiberglass channel with FRP blade stop Designed for corrosive environments Flange mounted Chemical resistant epoxy glue and/or monel fasteners Damper can be installed in both horizontal and vertical airflow directionsAll Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. g. Ruskin is a leading manufacturer of dampers, louvers, air measuring, noise control and energy recovery products for various applications. The majority of designs are rated at 2 or 3 hours. max. Maximum rating of 4,000 fpm and 4" w. Greaves Rd. Grandview, MO 64030 View our location on Google Maps Phone: 816. Smoke dampers utilizing multiple actuators must have all actuators field wired to a common point for simultaneous closure. Ruskin offers blast suppression dampers which are custom designed to each application. Dampers shall be in all respects equivalent to Ruskin Model CDRS25. 3. a. 8) galvanized steel struc-Products. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 ® Nominal Diameter, Inches Total CFM. 2 m/s) and 4” w. Damper shall be, in all respects, equivalent to Ruskin model BD2A2. • For proper operation, damper must be installed square and free from racking. . specification but their recommendedThe ZMD60 Zone Mixing Damper is suitable for multiple zone applications where high performance is required. Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. 24VAC modulating actuators (spring return or fail-in-place) can. g. The damper shall be rated for dynamic closure at 2000 fpm (10. lbs. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Our plant in Thailand is well-equipped to manufacture next-generation products. The switch package shall include two position indication switches linked directly to the damper blade to provide full open and full closed damper. 01" w. STATIC PRESSURE IN IN. Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. The FSD60FA da mper may be installed. Ruskin CFD(R)2 and CFD(R)3 are UL Classified to provide protection to HVACRectangular Steel V-Groove. The CBDR82 damper blade willRuskin is pleased to announce the availability of Revit® 3-D files of select products. ©Ruskin October 2007 ® Spec FSD60-C-1007/Replaces FSD60/36-C-1206 APPLICATION The FSD60-C is two dampers in one. Damper shall be in all respects equivalent to Ruskin BD6. 6 psi to 44. Damper Sleeve Sleeve thickness must be equal to or thicker than the duct con-nected to it. The EFL closes and locks the damper when temperatures exceed 165°F (74°C)Ruskin FDR25SS is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). Counter Balanced Backdraft Damper. The operable blades are opened and closed manually, or with the use of an actuator. Minimum damper size for BD6 with SPC is 12" x 12" (305 x 305). static pressure. Pressure Relief Doors. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. The "H" dimension represents the required height to encompassRuskin model ARD25 is an automatic round control damper used for clean air circulation in heating, cooling, and ventilation systems. Ruskin FAST and PFMA are 20 gauge steel mounting angles designed and approved for use specifically with Ruskin fire and fire/smoke dampers. (1 kPa). Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. g. The CFD7T is UL555C Classified Ceiling Fire Damper for wood construction. Fire dampers shall be Ruskin model FD35. Learn more about the FSD60 and its installation. The FDR25 is rated for maximum velocity of 2,000 fpm and 4” w. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. for dampers up to 17. Ruskin CD60 Commercial Control Dampers Type for a low price! Get free shipping on orders over $999!March 23, 2022. Available with factory furnished sleeves. a. 8955From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. ) SUGGESTED SPECIFICATION STATIC PRESSURE (Inches Water Gage) AIR FLOW IN C. 25" w. It features: Maximum velocity of 4,000 fpm. Link Bar 5. Complete with 24V modulating actuator and field wired wall mounted, the thermostat gives individual control to office spaces with single or multiple branch ducting. Standard, 1 1/2 and 3 hr. The ratings shown are based on tests and procedures performed in accordance with AMCA Publica-tion 511 and comply with the requirements of the AMCA Certified Ratings Program. Noise Control. INSTALLATION For proper operation, damper must be installed square and free from racking. /Class III, V-Groove Blade,. Rev. Life Safety Products. • For proper operation, damper must be installed square and free from. Pressure drop and free area may vary. NOTES: 1. We always proudly labeled our literature with the AMCA Certified Ratings Logo and now we will be labeling on dampers as well. Ruskin CFD model ceiling fire dampers provide the appropriate protection needed for openings in fire rated ceilings. 4 psi respectively. Model ZCRD25 can also be supplied with Ruskin Cable drive systems. Noise Control. It features: Corrosion resistant backdraft protection from its stainless steel construction. Deflections in other damper widths (less than 48" [1219]) at Smoke dampers are UL555S tested and labeled, low leak damper and actuator assemblies constructed to restrict the spread of smoke in HVAC systems that are designed to be automatically shut down in the event of a fire, or opened to control the movement of smoke within a building when the HVAC system is part of an engineered smoke control system. Maximum velocity of 4,000 fpm. ft. Dimensions shown in parentheses ( ) indicate millimeters. Greaves Rd. Stops the leakage of smoke in static and dynamic smoke systems. Linkage shall be concealed, out of airstream, within the damper frame to reduce pressure drop and noise. While providing fresh air intake and exhaust, Ruskin Louvers can also provide architectural style to building design. They also offer a new coupler option that joins two damper sections without a jackshaft allowing an actuator to be mounted on side of frame to provide a narrow profile when space is limited. Stainless Steel V-Groove Blades. 5 hr. Pressure drop and free area may vary. The Damper part prices in this catalog do include freight within the contiguous 48 states. Opposed blade dampers must be operated from a power blade on the. Catalog. Performance curves based on AMCA Standard 500 using test setup appratus figure 5. — Ruskin ® announces three new emergency generator inlet dampers (GenSet) designed to quickly open to relieve combustion air. A 1" (25) diameter jackshaft is normally used for. CDR25 and CDO25 dampers are round and oval volume control dampers. g. 2 m/s) and 4” w. These products are well suited for both retrofit applications as well as new construction. The AiQ-TD-50 offers accurate airflow measurement and control through electronicthermal dispersion technology utilized in Ruskin model TDP05K Airflow & Temperature Measuring probes(s) with the inclusion of Ruskin model CD50 control damper factory configured as one compact assembly. Ruskin's all aluminum damper for medium and low pressure commercial HVAC systems offers low leakage with a stan-dard, commercial built damper. It features: Airfoil blades, which have greater strength, produce less sound, greater sealing ability, and static pressure loss. AMCA licensed as a class 1A damper. Conservative ratings are presented intentionally in an effort to avoid misapplication. The TDPOSK is a highly accurate thermal dispersion airflow and temperature measuring probe. CDRS82 ROUND CONTROL DAMPER Spec CDRS82-102/Replaces CDRS82-193 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Actuators enable a damper to operate with controlled positioning throughout the stroke of the damper. (Consult Ruskin for detailed CSI MasterFormat Specification. com . Find the pressure drop across a 18" wide x 18" (457 x 457) high Model CD80AF4 control damper. Ruskin Literature. The factory mounted fast-acting 8-second spring open actuatorprovides optimal performance and reliability. Damper shall be tested and licensed in accordance with AMCA 511 for Air Performance and Air Leakage. w/ damper - - ELF6375DXD Horizontal drainable blade Wind-borne debris regions (non-essential buildings), HVHZ, areas with rain management system ±148 6” N/A TDI Water, Air 540 & 550 w/ damper ELC6375DXD Horizontal drainable combination louver/ damper Hurricane-prone regions, HVHZ, areas with rain management system, applications. Static only damper labels are not permissible. It also features: Frame corners that are internally braced to reduce racking. Ruskin® A 0 Page 1 CD60CE Critical Environment High performance 316 stainless steel airfoil blade damper AMCA Class IA Leakage Rated The High-Performing Ruskin Model CD60CE is designed to control and regulate air movement in medium to high velocity and pressure HVAC Systems. DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. g. (Consult for electronic version of this “Quick” spec as well as for complete 3- part CSI MasterFormat Specifications) Document Title Limited Warranty Document LINKS TO IMPORTANT DOCUMENTSFire and Smoke Dampers Ruskin actionair ES Series Operating And Maintenance Manual. of damper with minimum of 20 in. The commercial dampers provide low pressure openings with exceptional pressure drop performance, while the industrial line includes heavier gauge materials to. It features: Low leakage. Actuators are designed to operate reliably in smoke control systems requiring Underwriter’s Laboratories, Inc. and greater Carbon steel construction Butterfly bladeThe CFD7T-ST-BT is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548 and H502. EFL or PFL heat-actuated devices that permit closed closure through the actuator and are automatic remote resettable after test, smoke detection, or power. Commercial Control Dampers; Sound Control; Industrial Control Dampers; Software. Do not weld or fasten angles together at cor-ners of dampers. Dampers shall be in all respects equivalent to Ruskin Model CDRS25. 75" w. The damper is rated for5 82w ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowThe FSD60V Combination Fire/Smoke Damper is both UL555 and UL555S Classified. Horizontal mount dampers may be installed with the jackshaft above or below the floor. • Kansas City, MO 64030 • (816) 761-7476 vFBD35 IRIS BALANCINg DAMpER Ruskin IRIS Balancing Damper model VFBD35 is an excellent solu -For other damper sizes refer to Air Performance Data For All Smoke Dampers spec sheet. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Louver blades are . Smoke dampers utilizing multiple actuators must have all actuators field wired to a common point for simultaneous closure. Determine the airflow in CFM. Unlike other ceiling. Ruskin (Thailand) Co. 5 Hour for use in 2 Hour Walls. Supported by US Headquarters, Ruskin is the world largest and innovative air control solutions manufacturer, we combine financial stability with pioneering. The FSDR25C is a round tunnel corridor fire/smoke damper with UL555 Classification as a 1 ½ hour rated fire damper and a Leakage Class I UL555S Smoke Damper. Learn more about the features and. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Ruskin has a comprehensive line of air measuring, IAQ (Indoor Air Quality), and control solutions. We are the leading manufacturer of air and sound. UL555S rating up to 350°F (177°C). This damper is fitted with a counterweight assembly that can be field adjusted and calibrated to meet the specific airflow requirements of your unique system. Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and collection systems. Zone Control Systems. 765. Testing has proved that the CD40x2 insulated more efficiently than conventionally insulated blades. Industrial Fiberglass Louvers. 5hr Dynamic Fire Dampers » 3hr Dynamic Fire Dampers » 1. Ruskin fire/smoke dampers. The damper/actuator assembly is exposed to elevated temperatures for 30 minutes and then immediately cycled three times. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. FSD35. (2 kPa). FILES (0) Share this page: Trusted for decades, Ruskin V-Groove blade dampers were designed to extend a lower cost solution for standard duty (medium or low pressure) applications. Ruskin’s optional wireless damper Inspector™ , utilizing wireless communication protocol by EnOcean®, is the ideal solution for mandatory testing of motorized life safety dampers per NFPA* and Building Code requirements. Availability: Get a Quote. 21. The Ruskin Wireless Inspector™ includes the RFDI (Radio Frequency Damper Interface) located at each damper withCeiling Fire Dampers UL Classified Radiation Dampers for Wood Truss Construction The CFD7T is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586,. Email. Minimum damper size for BD6 with SPC is 12" x 12" (305 x 305). Ruskin Literature. 4) steel. This model offers the lowest AMCA leakageRuskin® is an authority in Air Distribution and Air Control products such as dampers, louvers and silencers. The SD60M is a UL555S Classified Leakage Class I modulating smoke damper. 8955DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. Dampers can be constructed of galvanized, stainless, or. Leading the industry with innovative designs, Ruskin aluminum airfoil blade dampers are constructed utilizing high yield 6063T6 extruded aluminum frame and blades. Maximum 8" static pressure UL approval for dual directional airflow Failsafe design, which enables the damper to automatically assume the desired. Must be installed in the factory. Some of the approved ceiling designs are L501,. II-FSD36-0121/ Replaces II-FSD36-514 ©Ruskin January 2021 ® APPLICATION The FSD35, FSD36 and FSD37 are combination fire and smoke dampers designed to restrict the passage of flame and resist the passage of smoke. the application of firestopping caulk in the annular space surrounding a fire or fire/smoke damper <b>is not. The Ruskin optional firestopping installation is one of our latest installation instruction supplements we offer. Use "Mount With Arrow Up" label as a guide for proper damper orientation. , Ltd. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. 2. g. Windstops all around. The Ruskin ® knowledgeable and dedicated rep network adds value by listening to customer’s needs and providing expert advice and nimble service. LEADS; TDP05K Placement Tool; Windload Calculator; Resources. The FSD60 can be installed in horizontal or vertical applications and has low leakage and pressure drop ratings. 7476 Fax: 816. b. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. Consult Ruskin or your Ruskin repre-sentative when damper is to be applied in conditions exceeding recommended maximums. Ruskin’s adjustable louvers and louver/damper combinations allow our customers to enjoy the benefit of architectural styling with air control and shut off. Spec FSDGA-216/Replaces FSDGA-1115 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION.